Tag Archives: Financial Losses

Financial loss refers to a decrease in monetary value, typically resulting from business operations, investments, or unforeseen events. It can occur due to poor decision-making, market fluctuations, operational inefficiencies, or external factors. Managing financial loss involves identifying causes, mitigating risks, and implementing strategies to protect financial stability.

Consequence of Weaknesses in Power Quality

In the mid-1980s, I embarked on a mission to resolve persistent “power failure” complaints from the National Accelerator Centre (NAC) in Faure, Western Cape, now known as iThemba LABS—the largest accelerator facility in the Southern Hemisphere. Invited for private tours, I delved into their operations, even entering the high-stakes environment of the operating room. Witnessing […]

Power Network Disturbances

Throughout my time in the power transmission and distribution industry I have probably had experiences that many others may never have. In a previous post, I talked about the current and voltage unbalances and how a large factory in the Western Cape in South Africa was severely affected by negative phase sequencing. In this post […]

Power Quality Issues Caused by Distributed Generation

To mitigate the effects of Load-Shedding, many homeowners have decided to install PV Solar Energy systems. And, as I said before, they are more worried about how much it would cost than the quality of the products. If they can pay the lowest possible price for the entire installation, they are happy and do not […]

Learn More About Rotating Voltage and Current Vectors

With our comprehensive Negative Phase Sequence Consulting Services, we deliver expert analysis and innovative solutions to effectively manage negative sequence currents in three-phase electrical systems. Our services are designed to identify and address issues caused by unbalanced loads, faults, and system abnormalities, ensuring system stability, reducing equipment wear, and significantly enhancing overall power quality. We […]

Learn the Hidden Impact of Untransposed Transmission Lines

Extremely long—hundreds of kilometers—untransposed high and extra-high voltage transmission lines with a flat, horizontal conductor configuration significantly contribute to negative-sequence voltages and, to a lesser extent, zero-sequence voltages. The incidence of negative-sequence voltages rises with increasing electrical load. In the late 1970s and early 1980s, Eskom operated two 400kV transmission lines to the Western Cape: […]

Phase Imbalance in Distribution Networks

In a balanced three-phase network, the magnitudes of the voltages and currents in all three phases are the same and these voltages and currents phase are shifted symmetrically by 120 degrees to each other. If the magnitudes are not the same and phase-shifts are different from the 120 degrees, the network is unbalanced. Eskom strive […]

Load Shedding Consequences

When switchgear is poorly maintained and operated continuously, it is only a matter of time before something significant occurs. However, if these extreme events go unnoticed, the consequences can be long-lasting. During load-shedding, circuit-breakers should be opened when load-shedding starts and closed when load-shedding ends. Unfortunately, the contacts of these circuit-breakers are often concealed. As […]