Introduction

The concept of “power quality” may seem abstract, especially when dealing with an intangible commodity like electricity. However, for commercial and industrial facility managers, it holds significant importance. Good power quality directly impacts productivity and employee safety. Conversely, poor power quality can lead to financial losses due to equipment damage, reduced productivity, and product spoilage. Recognizing and maintaining optimal power quality is essential for efficient operations and overall business success.

Economic Implications of Power Quality

Power quality, often overlooked but crucial, has significant economic implications. The Leonardo Power Quality Initiative estimates that poor power quality costs the European economy up to €150 billion annually, while in the U.S., losses range from $119 billion to $188 billion, as reported by the Electric Power Research Institute (EPRI). However, a pivotal finding by EPRI highlights that a staggering 80 percent of power-quality disturbances originate within a facility itself.

Impact of Renewable Energy on Power Quality

The data, although dated, suggests that the economy has experienced substantial growth. Additionally, network operators now heavily rely on renewable energy sources. However, this shift may have unintended consequences, potentially impacting power quality.

Sustainable Development and Power Quality

In the context of increased competitiveness, companies are increasingly concerned about sustainable development. Inadequate power quality (PQ) can lead to significant financial losses and impact a company’s sustainability.

Utility Charges and Imbalances

Utility companies charge commercial and industrial consumers based on both active power (kW) and reactive power (kVAR). Imbalances affect both. Reactive power (associated with voltage and current phase differences) increases due to imbalances, leading to additional charges. Moreover, higher losses from imbalances result in increased energy consumption, indirectly affecting consumer bills.

Challenges in South Africa

While energy providers and users worldwide recognize the urgency of addressing power quality issues, South Africa faces unique challenges. Despite an aging infrastructure, load fluctuations, and insufficient maintenance, power quality issues are not addressed adequately. Articles calling out Eskom, City Power, and NERSA have gone unanswered. Questions arise about NERSA’s role—does it merely issue licenses and approve tariff increases, or does it also manage safety and reliability compliance? It is time to raise awareness and demand accountability. End-users must advocate for higher-quality power, and utilities should prioritize improved power quality.

Balanced vs. Unbalanced Power Networks

In this document, I delve into the principles of balanced and unbalanced power networks, using real-world data to highlight the differences between these scenarios. Specifically, I address Eskom and other power distributors’ awareness of unbalanced network conditions and their actions to rectify them.

Financial Burden on Customers

Importantly, I explore how customers, who experience unbalanced networks, shoulder a substantial financial burden through their electricity bills. Meanwhile, electricity generators—whether from coal-fired power stations, nuclear sources, or renewable energy—may remain apathetic. The inefficiencies arising from unbalanced networks could inadvertently enhance their profits.

Conclusion

Primarily, it is crucial to understand that the zero-sequence component is responsible for generating heat in transformers and cables, hence the need for its elimination. Secondly, imbalanced network conditions lead to an extremely high neutral current and elevated circulating currents in the delta windings of transformers. These conditions can cause transformers and cables to overheat, potentially leading to unexpected shutdowns or even more serious failures like cables being burnt off or transformer insulation ignition.

Reflect on the recent surge in reported cable and transformer malfunctions, and then form your own opinion: Are Eskom and other power distributors cognizant of the imbalanced network conditions? Furthermore, do they take adequate measures to inspect the networks for this issue? Based on my observations, it seems unlikely. They appear to disregard any notifications concerning imbalanced network conditions.

A recurring query is: who reaps the benefits from the additional charges customers pay due to unbalanced network conditions? Let us delve into this. Customers require a certain amount of electrical power, or real power, to carry out specific tasks. However, these unbalanced network conditions lead to a substantial rise in inefficient powers, causing an increase in apparent power. Since customers’ bills are primarily based on this apparent power, they end up paying more for these inefficient powers. On the generation side, power must be produced to offset the losses. Each unit generated includes a profit margin. Therefore, the more units produced, the greater the profits. It is important to note that none of the power plants, whether coal-fired, nuclear, or renewable, operate as non-profit entities.

It might be beneficial for individuals like the Eskom executive to peruse this article, along with other articles I have shared on my blog. Additionally, web pages such as Symmetrical Component Analysis and Negative Phase Sequencing could provide further understanding of this concept.

Those who have comprehended the aforementioned information can independently determine the validity of the claim that Modderbee and Linden are not experiencing unbalanced network conditions.

What is crucial is that consumers need to determine if they are willing to pay a significantly higher price for electricity, considering that the issues should be resolved by the power supply distributors, including Eskom.

Equally significant is the fact that imbalances in networks are not readily apparent in power supplies. For instance, in Linden, individuals might assume the power supply is functioning normally by checking the phase-to-neutral voltages. Similarly, in Modderbee, Eskom and electricity department officials might perceive the network as problem-free when they observe that the phase-to-phase voltages are consistent.

If you are under the impression that residing in a different part of the globe shields you from unbalanced network conditions, it might be worth verifying that assumption. As outlined in this document, you might be totally unaware of such occurrences.

Newsletter

Our newsletters aim to enlighten our audience about current trends and events. We strive to distribute a newsletter at most once a week, but the frequency may vary to avoid inundating our website visitors with irrelevant content.

The most recent newsletters will be dispatched via email to all individuals on our mailing list and will also be accessible under this menu section.

Subscribe

* indicates required

Intuit Mailchimp

Posted in Best Practices, Power Quality Matters and tagged , , .